TK Truck Body located in Edmonton, Alberta, is a truck/van body manufacturer and fleet repair shop.
16445 130 Ave NW, Edmonton, AB T5V 1K5
Phone: 780 447 9529
Fax: 780 447 2468
We are available during scheduled operating hours to answer all inbound inquiries.
We are available during scheduled operating hours to answer all inbound inquiries.
For industrial jobsites or residential areas where noise level is a concern, there is no better system.
The VMAC Multifunction Power System, powered by a Cat® Industrial Diesel Tier 4F engine, includes six power sources in one compact, quiet system. With noise reduction panels, low and high idle controls and Standby Mode, operators can safely communicate while working without disturbing the jobsite or the neighbors. This self-contained system can be fully integrated into any diesel work truck fuel system or skid-mounted for stand-alone applications with an optional external fuel tank.
Components included:
Applications – Common jobs that use 6-In-1 Power Systems – Cat Power:
SIX POWER SOURCES, ONE QUIET MACHINE
For industrial jobsites or residential areas where noise level is a concern, there is no better system. The VMAC Multifunction Power System, powered by a Cat Industrial Diesel Tier 4F Engine, includes everything needed for safe operations on any jobsite in a single compact system. Components include: air compressor, generator, welder, booster/charger, PTO with optional hydraulic pump, and cold climate kit. With noise reduction panels, low and high idle controls and Standby Mode, operators can safely communicate while working without disturbing the jobsite or the neighbors.
EASY OPERATION & SWITCHING BETWEEN SYSTEMS
The VMAC Multifunction Power System allows operators to seamlessly switch between operations, without the hassle of complicated controls or maneuvering multiple machines on the jobsite. This means more time working, improving productivity and getting customers back to work faster. It is designed for ease of use, to run efficiently with only one operator.
SAVE TRUCK MAINTENANCE & FUEL COSTS
The VMAC Multifunction Power System reduces truck maintenance and improves fuel economy by allowing operators to turn their truck engine off while on the jobsite. Also, by reducing vehicle weight by up to 140 lb, automatically idling the Cat engine up/down with air demand and turning the Cat engine off/on with air demand, the VMAC Multifunction Power System allows operators to carry more tools or equipment or improve fuel economy.
AIR COMPRESSOR
Oil-injected rotary screw; belt-driven; 45 CFM @ 100 psi,100% duty cycle; Up to 175 psi.
AC/DC GENERATOR/WELDER/BATTERY CHARGER/BOOSTER
AC:
• 8 kW continuous output
• 1 x 30A, 240V, 60Hz 3 phase circuit (w/wo receptacles)
• 2 x 20A, 120V, 60Hz single phase circuit (w/wo receptacles)
DC: For battery boosting/charging; other DC loads
• Boost – 300A max @ 13V; Charge – 12V, 24V, 36V, 48V
• CC mode for SMAW and GTAW (stick/TIG welding)
• 250A @ 35% duty cycle; 190A @ 60% duty cycle
GENERATOR / WELDER CONTROL BOX
GENSET Voltage selector; Welding Current control and ARC force; Socket for optional Remote Welding Control.
Cat C1.1 INDUSTRIAL DIESEL ENGINE
Tier 4 final; Inline 3, 4-Stroke; Naturally Aspirated (Extended oil change interval 500 hrs/1 yr)
PTO PORT
Clutched SAE ‘A’ port with 9-toothed spline, 2,800 RPM output; 35 ft-lb continuous torque (max).
CONTROL/DIGITAL DISPLAY BOX
Remote mounted; electronic key switch; selector switches for PTO/GENSET/COMPRESSOR; LCD for compressor on/off controls, observing system status and adjusting parameters
BATTERY
Included AC Delco 12V, 460 CCA, 575 CA
AIR /OIL SEPARATOR TANK
Separates compressor oil from compressed air.
Air Compressor Output
45 CFM @ 100 psi (175 psi max)
Air Compressor Type
Belt-driven, 100% duty cycle, VMAC oil-injected rotary screw
Engine:
Cat C1.1 industrial diesel engine, Tier 4 final; Inline 3, 4-Stroke; Naturally Aspirated (Extended oil change interval 500 hrs/1 yr)
AC/DC Generator/Welder:
AC:
• 8 kW continuous output
• 1 x 30A, 240V, 60Hz three phase circuit (w/wo receptacles)
• 2 x 20A, 120V, 60Hz single phase circuit (w/wo receptacles)
DC: For battery boosting/charging; other DC loads
• Boost – 300A max @ 13V; Charge – 12V, 24V, 36V, 48V
• CC mode for SMAW and GTAW (stick/TIG welding)
• 250A @ 35% duty cycle; 190A @ 60% duty cycle
PTO Port/Hydraulics
Clutched SAE ‘A’ port with 9-toothed spline, 2,800 RPM output; 35 ft-lbs continuous torque max (Patented)
Hydraulic Pump: (optional)
Throttle Control:
2-speed throttle, responds to air demand
Battery:
AC Delco 12 V, 460 CCA, 575 CA
Control System:
Cold Climate Features:
Engine and compressor will wait until the temperatures are above 41°F (5°C) before loading and going into a running state
Weight (dry):
Approximately 710 lb (322 kg) (excluding optional fuel tank)
Dimensions:
Decibels (dB) @ 21 feet (6.4 meters):
74.25 dB at high idle, 69.75 dB at low idle, 0 dB in Standby Mode
Fuel Supply Options:
Air Receiver Tank (recommended, not included):
Minimum 10-Gallon Air Receiver Tank – Recommended for proper operation of all functions.
Warranty:
Two years on all major components; VMAC air-ends are covered by VMAC’s Lifetime Warranty (Limited)
For more information about VMAC’s Warranty, visit www.vmacair.com/warranty
OUR QUOTING PROCESS ALLOWS FOR HASSLE-FREE QUOTE SUBMISSION IN JUST A FEW MINUTES OR LESS!
WE ARE AVAILABLE MONDAY TO FRIDAY FROM 7:30AM - 4:00PM TO ANSWER ALL INBOUND INQUIRIES
TK Truck Body located in Edmonton, Alberta, is a truck/van body manufacturer and fleet repair shop.
16445 130 Ave NW, Edmonton, AB T5V 1K5
Phone: 780 447 9529
Fax: 780 447 2468
SALES: John office line 780 447 9535
PARTS: Mike E office line 780 447 9532
SERVICE: Tyler Trosko office line 587 416 2552